savina_MT-3655-2008
Images (5) Videos (0)
360° (1) Interactive (0)

Benefits

Clinical advancements in and out of the ICU
The Dräger Savina® is an advanced, high-quality ICU ventilator that offers excellent ventilation performance combined with easy operation. Designed for both adult and pediatric ventilation, the Savina® provides advanced therapy at any acuity level.
Comprehensive safety concept
An integrated safety concept makes the Savina® the natural choice for challenging environments, such as rural areas, earthquake zones or regions with erratic unreliable power grids. Its internal battery can bridge power failures of up to an hour, while an optional external battery can extend that range to 5 hours. Because air is supplied via an internal turbine, the Savina® requires no external source of compressed air – perfect for settings with limited infrastructure or where frequent transports are necessary. Integrated safeguard sensors for minute volume, airway pressure and 02 concentration ensure enhanced patient safety..
Increased flexibility
The Savina® gives you a full range of ventilation modes, both pressure- and volume-oriented, as well as pressure support, spontaneous breathing and non-invasive ventilation options. Built for adult and pediatric patients of all acuity levels, the Savina provides modern ventilation therapy for a very wide range of patients, situations and clinical settings.
Support the recovery process at every stage
The Savina’s AutoFlow® feature brings the benefits of spontaneous breathing to volume-oriented modes. BIPAP1 combines pressure-oriented ventilation with spontaneous breathing at any time and at any pressure level. The Savina’s non-invasive ventilation capabilities are further enhanced by highly sensitive triggering and effective leak management systems. Together, these features can help you reduce ventilation times, promote the weaning process, avoid reintubation and reduce the rate of pulmonary complications related to intubation.
Simple and effective user interface
An intuitive user interface makes learning to use the Dräger Savina® easy. Simply select a parameter, change the parameter and confirm that change. Changes are visually supported on the high-resolution color display. The Savina® can also display your choice of static, dynamic, graphic or numeric real-time or trend data on an optional 12” color touch screen.

Product Information

savina_br_9051453_en.jpg
Brochure Savina (PDF)

Clinical advancement, ease of use, versatility – in and out of the ICU

savina_br_9051657_en
Technical DataSheet Savina (PDF)

Clinical advancement, ease of use, versatility in and out of the ICU

Options

niv_br_9050398_en
NIV

Mask ventilation NIV for all your ventilation needs - from conventional to noninvasive ventilation
•Use of all ventilation modes
•Easy transition from invasive to non-invasive ventilator support
•Facilitate weaning effort
•Optimized alarm system
•Automatic leak compensation

Accessories

clinical_accessories_critical_care_MT-4738-2008
Complete Accessories Portfolio

For product details, please see the pdf of the accessories catalogues.

Downloads

vent_cc_100_years_pulmotor_booklet_en-1
Booklet: It began with the Pulmotor
One Hundred Years of Artificial Ventilation (PDF)

For Dräger, the history of ventilation is more than a sober chronological list – the history of ventilation is closely linked with the history of the Dräger family.

vent_cc_autoflow_book_en-1
Book Auto Flow® (PDF)

20 Questions – 20 Answers

vent_cc_bipap_book-1
Booklet: BIPAP (PDF)

Two Steps Forward in Intensive-Care Ventilation. An introductory guide to Evita ventilation

vent_cc_co2_book_en
Booklet: CO2-measurement during mechnical ventilation (PDF)

- Basic principles of ventilation
- Design of a ventilator
- CO2 monitoring
- Basic principles of CO2
- Interpreting capnograms

vent_cc_en_atc_ppse_book_en-1
Booklet: ATC and PPS
Breathing Support with Optimum Patient Comfort(PDF)

Today most users emphasize the need for spontaneous breathing ability during mechanical ventilation.

vent_cc_loops_book_en-1
Booklet: Curves and Loops in mechanical ventilation (PDF)

- Ventilation curve patterns
- Loops – a good thing all round
- Trends reviewed
- Capnography – keeping an eye on the details

ven_cc_kbws_habashi_success_en
CaseStudy Knowledge based weaning (PDF)

Protocolized Care in the Weaning Process

ven_cc_lewejohann_success_en
CaseStudy SmartCare™ (PDF)

Daily practice with SmartCare™ in a difficult to wean patient

ven_cc_smartcare_evolution_success_en
CaseStudy Evolution of Weaning with SmartCare™ (PDF)

Improving Intensive Care Unit (ICU) outcomes by reducing ventilator associated complications and ventilator days may to be achieved by re-engineering the weaning process.

ven_cc_smartcare_success_en
CaseStudy SmartCare™ (PDF)

Daily practice with SmartCare™ in a difficult to wean patient

ven_cst_SmartCare_mohlendick_en
CaseStudy Patient comfort and rapid weaning with Smart Care/PS (PDF)

A Case Description of a Patient Who was Difficult to Wean

ven_scps_UtahValley_success_en
CaseStudy SmartCare®/PS knowledge based weaning system: “Relentless” (PDF)

What are the challenges associated with weaning long-term patients from mechanical ventilation?

Related Products

Evita XL 360 Preview
Evita® XL

Move to the next level of excellence in invasive and non-invasive ventilation for adults, children and neonates with an advanced, multifunctional ventilator that will help you meet the challenges of modern respiratory care.

Evita 4 Edtion 360 Preview
Evita® 4 edition

The Evita® 4 has been recognized around the world as a leader in ventilation performance.

Evita 2 Dura 360 Preview
Evita® 2 dura

The Evita® 2 dura is an advanced intensive care ventilator with simple and versatile operation, a highly responsive flow trigger, and an open breathing system that gives both the patient and the clinician "Room to Breathe".

Carina International 360 Preview
Carina®

Flexible and compact NIV ventilator - the road to recovery!